Air conditioning Refrigeration and MGO cooling system
Air conditioning Refrigeration and MGO cooling system
1.1.Air Conditioner

Air Handling Unit
Cooling capacity: 25KW~1600KW
Cooling medium: fresh water
Heater: hot water, steam,thermal oil or electric
Humidify: manual, auto, hot water, fresh water or steam
Casing: double skins with 50mm insulation

Water cooled condenser unit
Cooling capacity: 25KW~405KW
Cooling medium: fresh water or sea water
Compressor: screw compressor, semi hermetic compressor or open type piston compressor
Refrigerant: R404a, R407c, R134a
Operating Voltage: 230/380/440/690V, 1/3ph, 50/60Hz

Water cooled deck unit
Cooling capacity: 25KW~500KW
Heater: hot water, steam, thermal oil or electric
Humidify: manual, auto, hot water, fresh water or steam
Cooling medium: fresh water or sea water
Compressor: screw compressor, semi hermetic compressor or open type piston compressor
Refrigerant: R404a, R407c, R134a
Operating Voltage: 380/440/690V, 3ph, 50/60Hz
1.2.Refrigeration and public refrigeration systems

Water cooled provision refrigerant plants
Cooling capacity: 1.5KW~35KW
Cooling medium: water cooled or air cooled
Refrigerant: R404a, R407c, R134a
Controller type: classic or PLC
Compressor: screw compressor, semi hermetic compressor or open type piston compressor
Operating Voltage:230/380/440/690V,1/3ph,50/60Hz
1.3.Packaged air conditioner

Water cooled packaged air conditioner
Cooling capacity:3KW~180KW
Cooling medium: fresh water or sea water
Heater: hot water, steam,thermal oil or electric
Humidify: manual, auto, hot water, fresh water or steam
Compressor: scroll compressor, semi hermetic compressor or open type piston compressor
Refrigerant: R404a, R407c, R134a
Operating Voltage: 230/380/440/690V, 1/3ph, 50/60Hz
Casing: galvanized sheet with paint or stainless steel
Evaporator: copper tube aluminum fins or copper tube copper fins
Controller: mechanical control or microcomputer control
1.4.MGO cooling system(Click to download 1.4 MGO cooling system.pdf)

MGO cooling system
- Acc. to maker's instruction
- No modification to booster
- Short Delivery
- Easy operation
- Europe marine quality
- Low investment
- Global Service
1.5.CFD simulation, design, installation and commissioning services for air conditioning and special ventilation systems

We design all the special ventilation systems and HVAC systems.We can also supply the computational fluid dynamics (CFD) simulation to show the efficiency of the special ventilation systems to provide a better and more safe solution for the customer.We have much experience for Double wall pipe ventilation, HVAC for Accommodation, Cargo-hold ventilation,Engine room ventilation for the ships of Cruise Vessel,Chemical Tanker, Multi-purpose Vessel,Ro-Pax,Ro-Ro,PCTC, LNG,LPG.